REA Final - 22 Dec 20 - eBook - 1682 pages
Understand, if we put a control joint at the bottom between the GRC base and the GWB shaft enclosure, there won't be another joint until we get to the soffits. We would put this centered in the soffits, to be within the 30' max CJ locations. This was indicated in the email below, that it is going to look like a monolithic piece as discussed during the summer. Lastly, I have re-attached the Plasterform shop detail for the soffit to capital. We have been planning to tape/spackle this joint, but the last correspondence said we cannot. Please advise. Sean Reed Project Manager Spearhead Construction, LLC MBE | WBE | SDVOB | SDVOSB | PANYNJ | NYCSBS Sean @ SpearheadCx.com Ph: 631.793.7422
The information contained in this email message is legally privileged and confidential information intended solely for the use of the intended recipient(s). If you are not the intended recipient(s), any distribution, dissemination, or reproduction of this email message is strictly prohibited. If you have received this message in error, please immediately reply to the sender and then destroy this message.
From: Trause, Zachary
Please advise if there is a visible control joint between soffit to GFRG capital as shown in the attached picture.
There should be no visible joints between the GWB ceiling and the GFRG truss capital. The transition between the curved GFRG and the sloped GWB should be taped, spackled and finished to a level 5 finish. Control joints in the sloped GWB ceiling following the trusses should be placed in alignment with the control joints which are centered on the ACT tech zone panels, as shown on the A22 drawings.
Zack Trause Project Engineer
SKANSKA WALSH Design-Build Joint Venture LaGuardia Airport CTB Replacement Project Hangar 5A Runway Drive Flushing, NY 11371 Mobile: (917) 565-6140 Think twice before you press "print."
This message, including any attachments hereto, may contain privileged or confidential information and is sent solely for the attention and use of the intended addressee(s). If you are not an intended addressee, you may neither use this message nor copy nor deliver it to anyone. In such case, you should immediately destroy this message and kindly notify the sender by reply email. Thank you. From: Sean