Division 01 -DOC STANDARDGENERAL CONDITIONS SINGLECONTRACT PROJECTS
-3...,..-........... , , DESIGN + CONSTRUCTION
Issue Date June 01, 2013 Revised - January 15, 2015
a. Manufacturer'swritten recommendations. b. Manufacturer's product specifications. c. Manufacturer's installation instructions. d. Standard color charts. e. Manufacturer'scatalog cuts. f. Wiring diagrams showing factory-installedwiring.
g. Printed performancecurves. h. Operational range diagrams. i. Mill reports. j. Standard product operation and maintenancemanuals. k. Compliancewith specified referenced standards. I. Testing by recognized testing agency. m. Application of testing agency labels and seals. n. Notationof coordination requirements. 5. Submit Product Data before or concurrent with Samples. 6. Submission of Product Data:
a. Initial Submission: The Contractor shall submit seven (7) sets of Product Data to the Design Consultant for his/her review and acceptance. The Design Consultant will transmit Product Data to appropriate sub-consultants for review and acceptance, including Commissioning Authority/Agent as applicable. A satisfactory catalogue cut will be stamped "No Exception Taken", be dated and distributed as follows: 1) Two (2) copies thereof will be returned to the Contractor by letter 2) Three (3) copies of the Product Data and copy of the transmittal letter to the Contractor will be forwarded to DOC 3) One copy will be retained by the Design Consultant 4) One copy will be forwarded/ retained by sub-consultant(s)as appropriate Should the Product Data be "Rejected" or noted "Revise and Resubmit" by the Design Consultant, the Design Consultant will return one (1) set of such Product Data to the Contractor with the necessary corrections and changes to be made indicated and one (1) set to DOC. 7. Revisions: The Contractor must make such corrections and changes and again submit seven (7) copies of each Product Data for the review of the Design Consultant. The Contractor shall revise and resubmit the Product Data as required by the Design Consultant until the submission is stamped "No Exceptions Taken" by the Design Consultant. However, Product Data which has been stamped "Make Corrections Noted" shall be considered an "Accepted" Product Data and NEED NOT be resubmitted. H. Samples of Materials: 1. For samples of materials involving electrical work of any nature, refer to Section 00 35 06 - General Electrical Requirements. 2. Samples shall be in triplicate, of sufficient size to show the quality, type, range of color, finish and texture of the material. 3. Each of the samples shall be labeled as follows: a. Name of the Project, DOC Project Number and Contract Number b. Name and quality of the material c. Date
SUBMITTAL PROCEDURES 01 33 00 - 7
Made with FlippingBook PDF to HTML5